Oxford Instruments IPS120_10#

Control the Oxford Instruments IPS120_10 power supply from Python with the IPS120_10 driver.

Driver: pymeasure
Type: Power supplies
Manufacturer: Oxford Instruments

Represents the Oxford Superconducting Magnet Power Supply IPS 120-10.

Publishing through instro#

instro publishes the commands you send to a IPS120_10 and the values you read from it, through any publisher. It takes two forms, both described in the pymeasure guide. Install with uv add "instro[pymeasure]".

With a PymeasureInstrument#

PymeasureInstrument wraps the driver in an instro instrument, with tags and background polling. The instrument is created inside the with block, and .device is the pymeasure instrument.

from pymeasure.instruments.oxfordinstruments import IPS120_10
from instro.pymeasure import PymeasureInstrument

with PymeasureInstrument(
    name="ips",
    instrument=IPS120_10("GPIB::25"),
    dataset_rid="<dataset rid>",
) as ips:

    ips.device.enable_control()         # Enables the power supply and remote control

    ips.device.train_magnet([           # Train the magnet after it has been cooled-down
        (11.8, 1.0),
        (13.9, 0.4),
        (14.9, 0.2),
        (16.0, 0.1),
    ])

    ips.device.set_field(12)           # Bring the magnet to 12 T. The switch heater will
                                # be turned off when the field is reached and the
                                # current is ramped back to 0 (i.e. persistent mode).

    print(self.field)           # Print the current field (whether in persistent or
                                # non-persistent mode)

    ips.device.set_field(0)            # Bring the magnet to 0 T. The persistent mode will be
                                # turned off first (i.e. current back to set-point and
                                # switch-heater on); afterwards the switch-heater will
                                # again be turned off.

    ips.device.disable_control()       # Disables the control of the supply, turns off the
                                # switch-heater and clamps the output.

With existing pymeasure code (attach())#

attach() adds publishing to pymeasure code you already have. The imports, the attach() call after the instrument is created, and recorder.close() are all that instro adds.

from pymeasure.instruments.oxfordinstruments import IPS120_10
from instro.lib import NominalCorePublisher
from instro.pymeasure import attach

ips = IPS120_10("GPIB::25")  # Default channel for the IPS
recorder = attach(ips, "ips", [NominalCorePublisher(dataset_rid="<dataset rid>")])

ips.enable_control()         # Enables the power supply and remote control

ips.train_magnet([           # Train the magnet after it has been cooled-down
    (11.8, 1.0),
    (13.9, 0.4),
    (14.9, 0.2),
    (16.0, 0.1),
])

ips.set_field(12)           # Bring the magnet to 12 T. The switch heater will
                            # be turned off when the field is reached and the
                            # current is ramped back to 0 (i.e. persistent mode).

print(self.field)           # Print the current field (whether in persistent or
                            # non-persistent mode)

ips.set_field(0)            # Bring the magnet to 0 T. The persistent mode will be
                            # turned off first (i.e. current back to set-point and
                            # switch-heater on); afterwards the switch-heater will
                            # again be turned off.

ips.disable_control()       # Disables the control of the supply, turns off the
                            # switch-heater and clamps the output.

recorder.close()  # flush and close the publishers

The examples are adapted from the pymeasure documentation for IPS120_10, which lists every property and method.