# Stream a sensor loop

Read two sensors every 100 ms for a minute, and stream both readings to a dataset. Points that can’t be sent go to a [fallback file](https://dev.nominal.io/nominal-streaming/guides/fallback.md), and errors are logged.

Replace `read_sensor` with your hardware reads, and the placeholder with your dataset RID. The program reads your API key and base URL from the profile that [API Keys Setup](https://dev.nominal.io/nominal-streaming/api-keys-setup.md) saves.

**Rust**

```shell
cargo add nominal-streaming nominal
cargo add tokio --features full
```

```rust
use std::time::{Duration, UNIX_EPOCH};

use nominal_streaming::prelude::*;
use nominal_streaming::stream::NominalDatasetStreamBuilder;

/// Stands in for your hardware: temperature in °C and pressure in kPa
fn read_sensor(i: u32) -> (f64, f64) {
    let t = f64::from(i) / 10.0;
    (24.0 + (t / 10.0).sin(), 101.3 + 0.2 * (t / 3.0).cos())
}

#[tokio::main]
async fn main() {
    // Load the API key and base URL that API Keys Setup saved
    let config = nominal::Config::load().expect("failed to read the Nominal config file");
    let profile = config.get_profile("default").expect("no profile named default");

    let token = BearerToken::new(profile.token()).expect("invalid API key");
    let dataset = ResourceIdentifier::new("<ri.catalog.instance.dataset.identifier>").expect("invalid dataset RID");

    let stream = NominalDatasetStreamBuilder::new()
        .stream_to_core(token, dataset, tokio::runtime::Handle::current())
        .with_options(NominalStreamOpts::default().with_base_api_url(profile.base_url()))
        .with_file_fallback("fallback.avro")
        .enable_logging_with_directive("warn")
        .build();

    let mut temperature = stream.double_writer(ChannelDescriptor::new("temperature"));
    let mut pressure = stream.double_writer(ChannelDescriptor::new("pressure"));

    let mut tick = tokio::time::interval(Duration::from_millis(100));
    for i in 0..600 {
        tick.tick().await;
        let now = UNIX_EPOCH.elapsed().unwrap();
        let (t, p) = read_sensor(i);
        temperature.push(now, t);
        pressure.push(now, p);
    }

    // Pass the writers' last points to the stream, then wait until everything is sent
    drop(temperature);
    drop(pressure);
    drop(stream);
}
```

**Python**

```shell
pip install nominal-streaming nominal
```

```python
import math
import pathlib
import time

from nominal.config import NominalConfig
from nominal_streaming import NominalDatasetStream, PyNominalStreamOpts

def read_sensor(i: int) -> tuple[float, float]:
    """Stands in for your hardware: temperature in °C and pressure in kPa."""
    t = i / 10
    return 24.0 + math.sin(t / 10), 101.3 + 0.2 * math.cos(t / 3)

# Load the API key and base URL that API Keys Setup saved
profile = NominalConfig.from_yaml().get_profile("default")

stream = (
    NominalDatasetStream(
        auth_header=profile.token,
        opts=PyNominalStreamOpts(base_api_url=profile.base_url),
    )
    .enable_logging("warn")
    .with_core_consumer("<ri.catalog.instance.dataset.identifier>")
    .with_file_fallback(pathlib.Path("fallback.avro"))
)

# Leaving the block sends what's buffered and closes the stream
with stream:
    for i in range(600):
        now = time.time_ns()
        temperature, pressure = read_sensor(i)
        stream.enqueue("temperature", now, temperature)
        stream.enqueue("pressure", now, pressure)
        time.sleep(0.1)
```

If the network drops, the stream keeps taking readings: requests it can’t send go to `fallback.avro`, with the stream’s start time added to the name. [Fallback file](https://dev.nominal.io/nominal-streaming/guides/fallback.md#upload-the-file) covers uploading that file later.