Fluke8808A#
- class Fluke8808A(visa_resource: str | VisaConfig)[source]#
Bases:
DMMDriverBaseFluke 8808A on its RS-232 port, primary display only. Resolution is set via
set_digits.Configure the driver; the port is not opened until
open().The front panel is locked (
RWLS) while the driver holds the meter, so the function it tracks can’t be changed underneath it.- Parameters:
visa_resource (str | VisaConfig)
ASRL resource string, e.g.
"ASRL3::INSTR"or"ASRL/dev/ttyUSB0::INSTR", or aVisaConfigwhoseserial_configmatches the meter’s front-panel RS-232 setup. The defaults (9600 baud, 8N1, no flow control) match the factory setup.
Example
>>> from instro.dmm import InstroDMM >>> from instro.unstable.dmm.drivers import Fluke8808A >>> dmm = InstroDMM(name="fluke", driver=Fluke8808A("ASRL/dev/ttyUSB0::INSTR")) >>> dmm.open() >>> dmm.read_dc_voltage()
Methods
Return the meter to local control and close the port.
Trigger an AC-current measurement and return the value (amperes RMS, vendor-dependent).
Trigger an AC-voltage measurement and return the value (volts RMS, vendor-dependent).
Trigger a DC-current measurement and return the value (amperes).
Trigger a DC-voltage measurement and return the value (volts).
Trigger a 4-wire-resistance measurement and return the value (ohms).
Trigger a 2-wire-resistance measurement and return the value (ohms).
Open the port and reset the meter into remote mode with the front panel locked.
Set AC-current integration time to
nplcpower-line cycles.Set manual AC-current range to
valueamperes;Noneselects auto-range.Set AC-voltage integration time to
nplcpower-line cycles.Set manual AC-voltage range to
valuevolts;Noneselects auto-range.Set integration time directly in seconds.
Set DC-current integration time to
nplcpower-line cycles.Set manual DC-current range to
valueamperes;Noneselects auto-range.Set DC-voltage integration time to
nplcpower-line cycles.Set manual DC-voltage range to
valuevolts;Noneselects auto-range.Set resolution: 5 selects the slow rate (2.5 rdg/s), 4 the fast rate (100 rdg/s).
Set 4-wire-resistance integration time to
nplcpower-line cycles.Set manual 4-wire-resistance range to
valueohms;Noneselects auto-range.Select
functionon the primary display.Set 2-wire-resistance integration time to
nplcpower-line cycles.Set manual 2-wire-resistance range to
valueohms;Noneselects auto-range.- open() None[source]#
Open the port and reset the meter into remote mode with the front panel locked.
- set_measurement_function(
- function: MeasurementFunction,
Select
functionon the primary display.
- set_digits(n: int) None[source]#
Set resolution: 5 selects the slow rate (2.5 rdg/s), 4 the fast rate (100 rdg/s).
The medium rate has the same 4.5-digit resolution as fast, so it is not reachable here.
- set_dc_voltage_range(value: float | None) None[source]#
Set manual DC-voltage range to
valuevolts;Noneselects auto-range.
- set_ac_voltage_range(value: float | None) None[source]#
Set manual AC-voltage range to
valuevolts;Noneselects auto-range.
- set_dc_current_range(value: float | None) None[source]#
Set manual DC-current range to
valueamperes;Noneselects auto-range.
- set_ac_current_range(value: float | None) None[source]#
Set manual AC-current range to
valueamperes;Noneselects auto-range.
- set_two_wire_resistance_range(value: float | None) None[source]#
Set manual 2-wire-resistance range to
valueohms;Noneselects auto-range.
- set_four_wire_resistance_range(value: float | None) None[source]#
Set manual 4-wire-resistance range to
valueohms;Noneselects auto-range.
- measure_ac_voltage() float[source]#
Trigger an AC-voltage measurement and return the value (volts RMS, vendor-dependent).
- measure_dc_current() float[source]#
Trigger a DC-current measurement and return the value (amperes).
- measure_ac_current() float[source]#
Trigger an AC-current measurement and return the value (amperes RMS, vendor-dependent).
- measure_resistance() float[source]#
Trigger a 2-wire-resistance measurement and return the value (ohms).
- measure_four_wire_resistance() float[source]#
Trigger a 4-wire-resistance measurement and return the value (ohms).
Default raises
NotImplementedError; override on drivers whose instrument has dedicated sense leads (e.g. Agilent 34401A).
- set_aperture_seconds(seconds: float) None#
Set integration time directly in seconds.
Default raises
NotImplementedError. Mutually exclusive withset_aperture_nplcon a given driver — vendors typically expose one or the other.